Dimensioning of the required trench length or height – iteratively according to DWA-A 138-1 (10/2024), DWA-A 138 (04/2005) or ATV-A 138.

Dimensioning of the required length or height of the trench infiltration or alternatively the length of the pipe trench infiltration using pipe runs.
Iterative calculation using rainfall intensities for selected duration levels and return periods. Storage coefficients according to DWA-A 138-1 or DWA-A 138.
Calculation with the location-specific rainfall intensity according to Reinhold (r(D=15min,n=1)).